2P Surge Protector 40KA AC SPD Arrester Device Lightning Protection

1,345.002,500.00 (-46%)

In stock

  • 40KA AC 2P SPD House Surge Protector protection Protective Arrester Device Lightning Protection
  • Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage;
  • Standard: IEC/EN 61643-1
  • Protect electric system and on-loading electrical apparatus from thunder  and instantaneous over-voltage;
  • Short circuit current: up to 10kA (8/20μs);
  • Protect electric system and on-loading electrical apparatus from lightening and instantaneous over-voltage;
Compare
SKU: 40KA-AC-SPD Categories: ,
Desription:
A 2P SPD 40KA AC SPD 2P House Surge Protector protection Protective Arrester Device Lightning Protection Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.

Principle

2P SPD is designed to limit transient overvoltages of atmospheric origin and divert current waves to earth, so as to limit the amplitude of this overvoltage to a value that is not hazardous for the electrical installation and electric switchgear and controlgear.

SPD eliminates overvoltages

  • in common mode, between phase and neutral or earth;
  • in differential mode, between phase and neutral.

In the event of an overvoltage exceeding the operating threshold, the SPD

  • conducts the energy to earth, in common mode;
  • distributes the energy to the other live conductors, in differential mode.

The three types of SPD

Type 1 SPD

The Type 2P SPD is recommended in the specific case of service-sector and industrial buildings, protected by a lightning protection system or a meshed cage.

It protects electrical installations against direct lightning strokes. It can discharge the back-current from lightning spreading from the earth conductor to the network conductors.

Type 1 SPD is characterized by a 10/350 µs current wave.

Type 2 SPD

The Type 2P SPD is the main protection system for all low voltage electrical installations. Installed in each electrical switchboard, it prevents the spread of overvoltages in the electrical installations and protects the loads.

Type 2 SPD is characterized by an 8/20 µs current wave.

Type 3 SPD

These 2P SPD have a low discharge capacity. They must therefore mandatorily be installed as a supplement to Type 2 SPD and in the vicinity of sensitive loads.

Type 3 SPD is characterized by a combination of voltage waves (1.2/50 μs) and current waves (8/20 μs).

thermometer is a device that measures temperature or a temperature gradient (the degree of hotness or coldness of an object). A thermometer has two important elements: (1) a temperature sensor (e.g. the bulb of a mercury-in-glass thermometer or the pyrometric sensor in an infrared thermometer) in which some change occurs with a change in temperature

Additional information

Weight0.40 kg
Dimensions15 × 12 × 10 cm
Be the first to review “2P Surge Protector 40KA AC SPD Arrester Device Lightning Protection”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

See It Styled On Instagram

    Instagram did not return a 200.

Main Menu

2P SPD

2P Surge Protector 40KA AC SPD Arrester Device Lightning Protection

1,345.002,500.00 (-46%)

Add to Cart